CA Outdoor Series
 |
- Outdoor Packaged Energy Recovery Ventilator
- Cost effective energy recovery for virtually any air handling system
- Complete flexibility in locating field supplied blowers – great for acoustically sensitive applications
- Typical Airflow Range of 500-4,400 cfm covered by Three Models:
- CA2XRT: 500-2,200 cfm - AHRI 1060 Certified Core - Two L125-G5
- CA3XRT: 750-3,300 cfm - AHRI 1060 Certified Core - Three L125-G5
- CA4XRT: 1,000-4,400 cfm - AHRI 1060 Certified Core - Four L125-G5
|
Standard Features:
- Utilizes RenewAire's exceptional static plate energy exchange core
- AHRI certified performance data for efficiency and cross leakage
- Ten year core performance warranty
- Suitable for restroom exhaust
- No liquid water (condensate) or accompanying drain line to deal with - as with many competing brands
- Hinged and latched access door to ERV cores with airtight outdoor exposure compression seals
- Built-in pressure ports with captive plugs allowing cross-core pressure measurement and accurate airflow measurement
- Low velocity intake hood with aerodynamic rain excluder
- One inch thick dense fiberboard insulation with scrimmed foil facing – washable, durable and easy to maintain – no loose insulation fibers to break off and enter the airstreams
- UL tested flammability and smoke generation that meets NFPA 90A and 90B test standards for commercial applications
- MERV 8, 2” pleated, 20”x20” nominal size filters as follows:
- CA2XRT: Four total, two for each airstream
- CA3XRT: Six total, three for each airstream
- CA4XRT: Eight total, four for each airstream
Available Options:
- Double wall construction
- Exterior paint – white standard – custom colors available
PA Series
 |
- Indoor Cabinets of ERV Cores
- Cost effective energy recovery for virtually any air handling system
- Field assembled into AHU systems or integrated into custom packaged air handlers
- Can be ordered factory assembled or disassembled for field assembly
- Field assembly allows ingress into tight spaces, equipment rooms, or through access hatches
- Complete flexibility in locating field supplied blowers
- Typical Airflow Range of 1,500-13,200 cfm covered by Four Models:
- PA6X: 1,500-6,600 cfm - AHRI 1060 Certifified Core - Six L125-G5
- PA8X: 2,000-8,800 cfm - AHRI 1060 Certifified Core - Eight L125-G5
- PA9X: 2,250-9,900 cfm - AHRI 1060 Certifified Core - Nine L125-G5
- PA12X: 3,000-13,200 cfm - AHRI 1060 Certifified Core - Twelve L125-G5
- Can be arranged in multiple units accommodating unlimited airflow capacities
|
Standard Features:
- Utilizes RenewAire's exceptional static plate energy exchange core
- AHRI certified performance data for efficiency and cross leakage
- Ten year core performance warranty
- Suitable for restroom exhaust
- No liquid water (condensate) or accompanying drain line to deal with - as with many competing brands
- Latched access doors (2 or 3 doors depending on model), each with airtight compression seals, allowing complete access to ERV cores from top of cabinet
- One inch thick dense fiberboard insulation with scrimmed foil facing – washable, durable and easy to maintain – no loose insulation fibers to break off and enter the airstreams
- UL tested flammability and smoke generation that meets NFPA 90A and 90B test standards for commercial applications
- MERV 8, 2” pleated, 20”x20” nominal size filters as follows:
- PA6X: Twelve total, six for each airstream
- PA8X: Sixeen total, eight for each airstream
- PA9X: Eighteen total, nine for each airstream
- PA12X: Twentyfour total, twelve for each airstream
CA Indoor Series
 |
- Indoor Cabinets of ERV Cores
- Cost effective energy recovery for virtually any air handling system
- Field assembled into AHU systems or integrated into custom packaged air handlers
- Compact design allows ingress into tight spaces, equipment rooms, or through access hatches
- Complete flexibility in locating field supplied blowers
- Typical Airflow Range of 500-4,400 cfm covered by Three Models:
- CA2XIN: 500-2,200 cfm - AHRI 1060 Certifified Core - Two L125-G5
- CA3XIN: 750-3,300 cfm - AHRI 1060 Certifified Core - Three L125-G5
- CA4XIN: 1,000-4,400 cfm - AHRI 1060 Certifified Core - Four L125-G5
- Can be stacked (up to five high with support structure) to accommodate up to 20,000 cfm
|
Standard Features:
- Utilizes RenewAire's exceptional static plate energy exchange core
- AHRI certified performance data for efficiency and cross leakage
- Ten year core performance warranty
- Suitable for restroom exhaust
- No liquid water (condensate) or accompanying drain line to deal with - as with many competing brands
- Hinged and latched access doors (2) with airtight compression seals, allowing complete access to to cores from both ends
- One inch thick dense fiberboard insulation with scrimmed foil facing – washable, durable and easy to maintain – no loose insulation fibers to break off and enter the airstreams
- UL tested flammability and smoke generation that meets NFPA 90A and 90B test standards for commercial applications
- MERV 8, 2” pleated, 20”x20” nominal size filters as follows:
- CA2XIN: Four total, two for each airstream
- CA3XIN: Six total, three for each airstream
- CA4XIN: Eight total, four for each airstream
Available Options:
|
|