Application Type:Indoor
Ventilation Type:Static plate, heat and humidity transfer
Typical Airflow Range:1,000-4,250 CFM
AHRI 1060 Certified Core:Four L125-G5
OA Filter(s):Total Qty. 6, (4) MERV 8: 20" x 20" x 2" and (2) 20" x 14" x 2"
RA Filter(s):Total Qty. 6, (4) MERV 8: 20" x 20" x 2" and (2) 20" x 14" x 2"
Dimensions:97" L x 108" W x 62 1/2" H
Weight:1,885-2,514 lbs. (varies by option)
Installation Location
[IN] Indoor Unit
Orientation
A

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

R

Electrical Service
[35] 208-230V / 3 Phase / 60 Hz
[34] 460V / 3 Phase / 60 Hz
[38] 575V / 3 Phase / 60 Hz
Supply Air Motor
[X] TEFC Direct Drive - 5 HP
Exhaust Air Motor
[X] TEFC Direct Drive - 5 HP
Controls
[-] Standard Unit Control Wiring
Integrated Programmable Controls - Premium
BACnet Factory Activation Available
Disconnect
[N] Non-fused (Standard)
[F] Fused
Coil Type
[DX] DX Coil - 1 Circuit
[DU] DX Coil - 2 Circuit
[CW] Chilled Water Coil
[XB] Heat Pump Coil - 2 Circuit
[XH] DX Coil + Hot Water Coil - 1 Circuit
[DH] DX Coil + Hot Water Coil - 2 Circuit
[CH] Hot Water Coil + Chilled Water Coil
[SC] Coil for Hot Water & Chilled Water
[HW] Hot Water
[-] No Coil or Field Installed​
Filter Type
MERV 8 (Standard)
Filter Monitor
[-] None
[F] Filter Monitor Both Airstreams
Wall
[S] Single (Standard)
[D] Double
Paint
[-] None
[W] White Paint
[C] Custom Paint
Controls
Digital Time Clock, SL, EV, EV Premium, HE, LE, RD, P/N 131300
Wall Mount, TC7D-W
Digital Time Clock, SL, EV, EV Premium, HE, LE, RD, P/N 131301
Exterior Enclosure, TC7D-E
Occupancy Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131302
Ceiling Mount, MC-C
Occupancy Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131303
Wall Mount, MC-W
CO2 Sensor, SL, EV Premium, HE, LE, RD, DN, P/N 131304
Wall Mount, CO2-W
CO2 Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131305
Duct Mount, CO2-D
IAQ Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131307
Duct Mount, IAQ-D
IAQ Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131308
Wall Mount, IAQ-W
Smoke Detector, HE, LE, RD, DN, P/N 102396
Duct Mount, SD-D
Remote Display, HE, LE, RD, DN, P/N 131311
Units with Enhanced or Premium Controls, Handheld/Wall Mount RD-M
Room Pressure Sensor, HE, LE, RD, DN, P/N 131314
Sensor with Display, Units with Premium Controls, RPS-WD 
Room Pressure Sensor, HE, LE, RD, DN, P/N 131310
Sensor without Display, Units with Premium Controls, RPS-WOD 
Duct Static Pressure Sensor, HE, LE, RD, DN, P/N 131315
Sensor with Display, Units with Premium Controls, DPS-WD 
Duct Static Pressure Sensor, HE, LE, RD, DN, P/N 131309
Sensor without Display, Units with Premium Controls, DPS-WOD 
Temperature Sensor Kit, HE, LE, RD, DN, P/N 131318
Units with Premium Controls for non-integrated heating, TS 
BACNet License Field Request, HE, LE, RD with Enhanced or Premium Controls, P/N 131316  
Filters
Filter, HE07 HE1.5, RD, HE-2XRTC, P/N 990080 
MERV 8 14"x20"x2" Single Filter
Filter, HE07, HE1.5, RD, HE-2XRTC, P/N 990091
MERV 8 14"x20"x2" Case of 12
Filter, HE07, HE1.5, RD, HE-2XRTC, P/N 990300
MERV 13 14"x20"x2" Single Filter
Filter, HE, CA, PA, RD, DN-3, P/N 990083
MERV 8 20"x20"x2" Single Filter
Filter, HE, CA, PA, RD, DN-3,  P/N 990084
MERV 8 20"x20"x2" Case of 12
Filter, HE, CA, PA, RD, DN-3, P/N 990303
MERV 13 20"x20"x2" Single Filter
Filter Set, RD4X, P/N 990441
MERV 8
Mounting
Select four isolators per unit with the proper load ratings per unit corner weights. See weight and center of gravity table in IOM.
Electric Duct Heater CSI (French)
Gas Furnace CSI (French)
Static-Gas-Furnace-CSI | PDF (196KB)
Static-Gas-Furnace-CSI | Word Doc (22KB)
RD4XIN CSI
RD4XIN | PDF (123KB)
RD4XIN | Word Doc (53KB)
Gas Furnace CSI
Static Gas Furnace CSI | PDF (196KB)
Static Gas Furnace CSI | Word Doc (22KB)
Electric Duct Heater CSI